HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
140 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: If you issue the INITIALIZE SAVE_CONFIGURATION CLI command on a
JBOD disk to save the controller configuration while the unit is not above the
container, the command appears to work, but the save operation does not occur. You
must place the unit above the JBOD, and then issue the INITIALIZE
SAVE_CONFIGURATION to accomplish this task.
Syntax
INITIALIZE container-name
Parameters
The following parameter supports the INITIALIZE command:
container-name
Specifies the container to initialize. This is the same name given to the disk or
storageset after it was created using the ADD command (for example, ADD
DISKS, ADD STRIPESETS, and so forth).
Switches
The following switches are are available for the INITIALIZE
container-name command:
Geometry switches
CAPACITY
CYLINDERS
HEADS
SECTORS_PER_TRACK
CHUNKSIZE
DESTROY and NODESTROY
DESTROY_MBR
SAVE_CONFIGURATON and NOSAVE_CONFIGURATION
These switches are described in the following paragraphs.