HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
148 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Facilitates discovery of the physical location of configured units, storagesets, and
devices by flashing the device fault LED on the front of the storage device. A
flashing LED helps to distinguish between located devices and failed devices.
The LOCATE command causes the device fault LED to function as follows:
Flashes once per second on a good device. The LED turns off with the
LOCATE CANCEL command.
Illuminates continuously on a failed device. The LED stays on even after
being turned off with the LOCATE or CANCEL command.
Note: The LOCATE command can also be used to test the device fault LED.
Not all devices provide a device fault LED; therefore, these devices cannot be
identified using the LOCATE command.
Syntax
LOCATE <parameter>
Parameters
The following parameters support the LOCATE command:
ALL
CANCEL
container-name
DISKS
ptl
UNITS
unit-number
These parameters are described in the following paragraphs.
LOCATE