HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
151HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Creates a one-member mirrorset from a single disk and names it.
Note: This command is
only used
on disks already configured as units.
Use the ADD MIRRORSETS command to create a mirrorset from disk drives not
already members of higher-level containers.
After the disk drive is converted to a mirrorset, increase the nominal number of
members by entering the SET mirrorset-name
MEMBERSHIP=number-of-members command, then enter the SET
mirrorset-name REPLACE=disk-name command to add more members
to the mirrorset.
Caution: If you change this cache setting, you should do so with minimal or
no load to the controller. If you do so, the controller can become inoperable
after the change in this setting takes place.
Syntax
MIRROR disk-name mirrorset-name
Parameters
The following parameters support the MIRROR command:
disk-name
mirrorset-name
These parameters are described in the following paragraphs.
disk-name
Specifies the name of the disk to convert to a one-member mirrorset. The disk
must be part of a unit.
MIRROR