HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
155HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Turns off the power to the subsystem enclosure. The command applies to BA370
enclosure configurations.
Note: Stop all I/O operations between the hosts and controllers before issuing a
POWEROFF command.
Syntax
POWEROFF
Parameters
There are no parameters associated with this command.
Switches
The following switches support the POWEROFF command:
BATTERY and BATTERY_OFF
OVERRIDE_BAD_FLUSH and NO_OVERRIDE_BAD_FLUSH
SECONDS
These switches are described in the following paragraphs.
BATTERY _ON
BATTERY_OFF
(default)
Instructs the external cache battery (ECB) charger to turn off or remain on.
Specify BATTERY_ON to keep the ECB charger on after the POWEROFF
command is issued.
Specify BATTERY_OFF to turn off the ECB charger after the
POWEROFF command is issued.
POWEROFF