HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
160 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Example
To remove DISK20100, DISK20200, and DISK40200 from their respective
mirrorsets, enter the following commands shown in Figure 4.
Figure 4: Removing disks from a mirrorset
See Also
ADD MIRRORSETS
MIRROR
RUN (CLONE utility)
SET mirrorset-name
SHOW MIRRORSETS
CLI> SHOW STRIPE1
Name Storageset Uses Used by
----------------------------------------------------------------------
STRIPE1 stripeset MIRR1 D104
MIRR2
MIRR3
CLI> SHOW MIRRORSETS
Name Storageset Uses Used by
----------------------------------------------------------------------
MIRR1 mirrorset DISK10100 STRIPE1
DISK20100
MIRR2 mirrorset DISK10200 STRIPE1
DISK20200
MIRR3 mirrorset DISK30300 STRIPE1
DISK40200
CLI> REDUCE DISK20100 DISK20200 DISK40200
CLI> SHOW MIRRORSETS
Name Storageset Uses Used by
----------------------------------------------------------------------
MIRR1 mirrorset DISK10100 STRIPE1
MIRR2 mirrorset DISK10200 STRIPE1
MIRR3 mirrorset DISK30300 STRIPE1