HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
171HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Caution: Run the
DILX
utility in the Autoconfigure mode only at initial
installations. If write operations are enabled, the
DILX
utility may overwrite
existing data.
The Autoconfigure mode is the most thorough mode and allows you to:
Automatically test all of the disk units configured.
Automatically perform thorough tests on all units with write
operations enabled.
The Standard mode is more flexible and allows you to:
Test selected disks.
Perform tests in Read-only mode or Write-only mode.
Provide run time and performance summary option.
Run in Read-only mode.
DIRECT—A command used to display a list of all executable diagnostic
or utility programs.
DSTAT—This is not a user utility. This utility is used by HP authorized
service providers only.
DWNGRDThis is not a user utility. This utility is used by HP
authorized service providers only.
FMU (Fault Management Utility)—A utility used to control several
spontaneous errors. FMU also displays information regarding the most
recent controller and memory system failure.
FRUTIL (Field Replacement Utility)—A utility used if you are replacing
a failed controller, external cache battery, or cache module.
HSUTIL—A utility used to format a disk device or to download new
firmware to a tape or disk device.
VTDPY (Virtual Terminal Display)—A utility used to display the current
controller state, performance data, processor utilization, host post activity
and status, device state, logical unit state, cache performance, and I/O
performance.
Refer to the controller troubleshooting guide for more information regarding
these utilities.