HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
232 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
RESUME
SUSPEND
These switches are described in the following paragraphs.
ADD=remote-node-name\target-unit-name
Specifies a unit to add into the remote copy set.
The remote-node-name is the name of the controller pair that controls the
unit that is to be added. This name is assigned through the REMOTE_COPY
switch of the SET controller command.
The target-unit-name is the name of the unit to be added to the remote
copy set.
ERROR_MODE=FAILSAFE
ERROR_MODE=NORMAL
(default)
Controls how and whether write operations occur on remote copy set
members. Two options are available:
Specify ERROR_MODE=FAILSAFE to enable Failsafe Lock mode for the
members of the remote copy. Failsafe lock is a condition the members of
the remote copy set assume under certain potentially catastrophic error
conditions. The failsafe lock condition disables access to the remote copy
set members.
Specify ERROR_MODE=NORMAL to allow write operations to continue
even if an error condition is present.
INITIATOR=initiator-unit-name
Moves the role of initiator to the specified target member.
Note: This command is part of the site failover procedure. Use of this switch is
restricted to only site failover conditions. Refer to the latest version of the Operations
Guide for the HP StorageWorks Data Replication Manager application for examples
of usage.