HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
266 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: The system displays the following messages after issuing the SHOW
ELEVATION command if a controller is not configured, inoperable, or missing.
For a controller that is missing or not configured:
*********************************************************
Other controller information in full (SHOW OTHER FULL).
*********************************************************
Error 6070: Illegal command -- this controller not
configured for dual-redundancy
For a controller that is inoperable:
*********************************************************
Other controller information in full (SHOW OTHER FULL).
*********************************************************
Error 6080: Command illegal at this time -- this
controller configured for dual-redundancy, but the other
controller is not running or not configured for
redundancy. Correct this condition and re-issue the
command.
Note: Before escalating support calls to an HP support representative, issue the
following commands and capture subsequent screen displays from each controller at
the time a controller problem is suspected. Capture screen displays as close to the
actual occurrence of the problem as possible (that is, before controller restarts).
CLI> SHOW ELEVATION
CLI> RUN FMU
FMU> SHOW LAST ALL FULL
FMU> SHOW DEVICE_ERROR
FMU> SHOW DEVICE_INFO
FMU> EXIT
For additional information on the above
FMU
commands, refer to the
HP
StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Troubleshooting Guide
.