HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
52 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
An association set is a group of remote copy sets that shares common attributes
(See SET association-set-name for the attribute list). This command
adds an association set to the pair of controllers. The association set can be
initialized with a single remote copy set through the use of the
SET remote-copy-set-name command. Additional remote copy sets can
be added to the association set with the SET association-set-name
command.
Note: This command is hidden and inoperative until the controller pair is put into
Remote Copy mode by specifying the REMOTE_COPY switch of the
SET
controller
command.
This command is valid only on the node on which the Initiator resides (where remote
copy sets are configured).
This command is rejected if the specified remote copy set is unknown to the
controller pair.
Syntax
ADD ASSOCIATIONS association-set-name remote-copy-set-name
Parameters
The following parameter is required for the ADD ASSOCIATIONS command:
association-set-name
Identifies the name of the association set. The association-set-name
can consist of a maximum of nine printable characters, excluding commas and
backslashes.
Note: Association sets cannot be renamed with the RENAME command. If the wrong
name is entered, the association set must be deleted and then added again.
ADD ASSOCIATIONS