HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
67HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Names a mirrorset and adds it to the controller configuration. Mirrorsets are often
referred to as RAID 1 storagesets. The data capacity of a RAID 1 is determined by
the storage size of the smallest member (base member size). You can have up to 6
physical disks drives per RAID 1 storagesets.
Syntax
ADD MIRRORSETS mirrorset-name disk-name1 [disk-nameN]
Parameters
The following parameters are required for the ADD MIRRORSETS command:
mirrorset-name
disk-name1
These parameters are described in the following paragraphs.
mirrorset-name
Assigns a name to the mirrorset container.
Note: This is the name used with the ADD UNITS command to identify the mirrorset
as a host-addressable unit.
The mirrorset name can consist of a maximum of nine printable characters,
excluding commas and backslashes.
A mirrorset is commonly named MIRRn, where n is a sequentially assigned,
unique identifier. Other naming conventions are acceptable, but this naming
convention presents both the type of container and a unique identifier for the
container in an intuitive manner.
disk-name1 [disk-nameN]
Identifies the disk drives making up the mirrorset. A mirrorset can contain one
to six disk drives.
ADD MIRRORSETS