HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)
FC Configuration Procedures
150 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Figure 37: Single controller cabling
Configuring a Single Controller Using CLI
To configure a single controller using CLI involves the following processes:
■ Verifying the Node ID and Checking for Any Previous Connections.
■ Configuring Controller Settings.
■ Restart the Controller.
■ Setting Time and Verifying all Commands.
■ Plugging in the FC Cable and Verify Connections.
■ Repeating Procedure for Each Host Adapter.
■ Verifying Installation.
Verifying the Node ID and Checking for Any Previous Connections
1. Enter a SHOW THIS command to verify the node ID:
SHOW THIS
See “Worldwide Names (Node IDs and Port IDs)” on page 55 for the location
of the sticker.
1 Controller
2 Host port 1
3 Host port 2
4 Cable from the switch to the host Fibre Channel
adapter
5 FC switch
CXO6881B
1
5
5
3
2
4
4