HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)
Preparing the Host System
110 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
HP StorageWorks Solution Software Installation 
There are two types of HP StorageWorks solution kit installation procedures. You 
can perform a new installation or an upgrade installation.
■ Perform a new installation if your system does not have a Cambex driver or 
any HP StorageWorks software installed. 
■ Perform an upgrade installation if you currently have a Cambex driver and/or 
HP StorageWorks software installed. 
New Installation
This type of installation assumes that you have no pre-existing solution software 
for HSG80 installed. To install the solution software, perform the following steps:
1. Create a directory on the target IBM server where the installation kit will 
reside by typing the command:
mkdir /AIX_Install
2. Obtain the IBM AIX Solution Kit for HSG80 from the website 
http://h18004.www1.hp.com/products/storagew orks/ma8kema12k/kits .html
. 
3. Click on the link for the IBM AIX Solution Kit.
4. Click the Download button and save the 
tar file to the install directory you 
created on the target system. 
5. Change the directory to the AIX install path by typing the command:
cd AIX_Install
6. Extract the kit from the tar file by typing the command:
tar xvf <AIX tar file>
7. Execute the installation script by issuing the command:
./INSTALL 
The following is the output of the installation script. Notes and explanations have 
been added. 
# ./INSTALL 