HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)
Planning a Subsystem
40 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
The CCL does the following:
■ Allows the RAID Array to be recognized by the host as soon as it is attached 
to the SCSI bus and configured into the operating system.
■ Serves as a communications device for the HS-Series Agent. The CCL 
identifies itself to the host by a unique identification string.
In dual-redundant controller configurations, the commands described in the 
following sections alter the setting of the CCL on both controllers. The CCL is 
enabled only on host port 1. At least one storage device of any type must be 
configured on host port 2 before installing the Agent on a host connected to host 
port 2.
Select a storageset that you plan to configure and that is not likely to change. This 
storageset can be used by the Agent to communicate with the RAID Array. 
Deleting this storageset (LUN) later breaks the connection between the Agent and 
the RAID Array.
Determining the Address of the CCL
CCL is enabled by default. Its address can be determined by entering the 
following CLI command:
HSG80 > SHOW THIS_CONTROLLER
Enabling/Disabling the CCL in SCSI-2 Mode
Enabling the CCL
To enable the CCL, enter the following CLI command:
HSG80 > SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
Disabling the CCL
To disable the CCL, enter the following CLI command:
HSG80 > SET THIS_CONTROLLER NOCOMMAND_CONSOLE_LUN
To see the state of the CCL, use the SHOW THIS CONTROLLER/ OTHER CONTROLLER 
command. Because the CCL is not an actual LUN, the 
SHOW UNITS command does 
not display the CCL location.