HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Configuring Windows NT/Windows 2000/Windows 2003 (32-bit) Clusters
266 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
Verify the Windows Registry Device Driver Parameters
The FCA device driver parameters in the Windows NT/Windows 2000/Windows
Server 2003 (32-bit) registry must be set correctly for proper operation of your
Enterprise & Modular Storage RAID Array storage subsystem configured in a
Windows NT/Windows 2000/Windows Server 2003 (32-bit) cluster. Locate the
registry key in your system as depicted in Figure A-2 and review the registry
setting values and compare them with the correct values that are listed in Table 17
(Note, all values are decimal unless noted). If discrepancies are found, run the
Fibre Channel Software Setup Utility and select the Custom button. Click on the
FCA Adapter Driver Setup option. This corrects the registry settings configured in
your system. Reboot your system after completing the Setup.
WARNING: StorageWorks does not recommend using the Registry Editor to
adjust registry settings. Fatal system errors may result.
Table 17: CPQKGPSA Device Driver Parameters
Driver Parameter
Transparent
Failover
Value
Multi-Bus
Failover
Value
EnableDPC 1 1
NodeTimeout 60 10
ElsRetryCount 6 6
LinkTimeOut NA 40
HLinkTimeOut NA 5
SimulateDevice 1 1
ResetTPRLO 2 2
EmulexOption 0xBA00 0xBA00
ErrRetryMax 0 0
QueueTarget 1 1
CrfIntrpt 1 1
CrfMsCnt 1 1
CrfRspCnt 8 8
QueueDepth 25 or 15 25 or 15