HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell NetWare Release Notes (AA-RV1NA-TE, March 2005)

Avoiding Problem Situations
35HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell
NetWare Release Notes
For more information, refer to the “What is the Command Console LUN?” and
Assigning Unit Numbers Depending on SCSI_VERSION” sections of Chapter 1
in the HSG80 ACS Solution Software V8.8 Installation and Configuration Guide.
Avoiding Problem Situations
Under certain conditions, you may experience unusual array controller behavior.
This section presents information to help you avoid such situations and to recover
from them if they occur.
Establishing an SWCC SCSI Connection
SWCC is not supported when Secure Path is installed on the servers and/or if
more than one FCA2210 HBA is installed in the system. For SWCC to connect to
an array, a LUN must be configured using CLI commands. HP recommends that
LUN 0 or LUN 100 not be used. In certain instances, if LUN 0 is used, LUNs with
IDs greater than D50 or D150 will not be recognized.
Note: In transparent failover mode, LUN D100 should not be used.