HP 1000/1500 Modular Smart Array Firmware Release Notes (592436-002, March 2011)

Active/Active firmware version: 7.2
Active/Passive firmware version: 5.4
Description
This firmware includes fixes to three issues and should be installed only if your environment has
experienced one of these issues. This release has undergone a full cycle of regression testing, but,
due to non-replication of the issues, only one issue and fix has been verified at HP test labs.
Product models
HP StorageWorks 1000 Modular Smart Array (MSA1000)
HP StorageWorks 1500 Modular Smart Array (MSA1500)
Operating systems
HP-UX 11.11, 11.23, 11.31
Microsoft Windows Server 2003 (x64, IA32, IA64)
Novell NetWare 6.5
Red Hat Enterprise Linux 3 (x64, IA32, IA64)
Red Hat Enterprise Linux 4 (x64, IA32, IA64)
Red Hat Enterprise Linux 5 (x64, IA32, IA64)
SUSE Linux Enterprise Server 9 (x64, IA32, IA64)
SUSE Linux Enterprise Server 10 (x64, IA32, IA64)
VMware 3.1, 3.5
Issues and Fixes
Issue: Fixed an issue of overlapping volumes when extending LUNs with the extend CLI command.
Test Status: Verified on Windows and Linux. Not verified on Tru64.
Issue: Resolved an issue of the MSA persistent reservation table becoming full when used with various supported
levels of VMware.
Test Status: Not Verified. Issue could not be reproduced in HP tests. Firmware versions 7.20 and 5.40 passed
regression tests running in a VMware 3.5 environment.
Issue: Incorporated additional checks and indications to ensure that the disk drive Fault LED will be lit during
a case of predictive failure. This is in addition to failure indications reported by host agents.
Test Status: Not Verified. Issue could not be reproduced in HP tests.
HP 1000/1500 Modular Smart Array Firmware Release Notes 3