HP StorageWorks 1000/1500 Modular Smart Array firmware updating guide (370881-002, June 2007)

3Updatingthecomponents
Perform the following procedures, as needed, to update system components:
Updating the operating system
Updating switch rmware
Updating HBA rmware
Updating SCSI ha rd drive rmware
Updating multipathing software
Updating HBA drivers, MPIO components, and the ACU
Updating MSA controller rmware
Updating the operating system
Obtain the ne ede d les and installation instructions from the operating system vendor website or the
HP IT Resource Center website: h
ttp://www.itrc.hp.com.
CAUTION:
Operating system updates require one or more system restarts and should be performed during
scheduled m
aintenance time.
Updating switch rmware
Obtain the needed les and installation instructions from the switch vendor or HP SAN Infrastructure
website:h
ttp://www.hp.com/go/san.
Updating HBA rm w are
Obtain the nee ded les and installation instructions from the HP SAN Infrastructure website:
h
ttp://www.hp.com/go/san.
NOTE:
SpecicversionsofHBArmware and HBA drivers are designed to work together . For more information,
see Determining which components to update and the MSA-specic compatibility guide on the Technical
Documentation page of each MSA website.
Updatin
gSCSIharddrivermwar e
SCSI har
ddrivermware updates are performed from the bootable ProLiant Firmware Maintenance CD
and are required only when the following message is displayed on the MSA controller LCD pa nel:
85 BAD DRIVE FRMWARE BOX <n> BAY <n>
CAUTION
:
This upd
ate procedure must be performed during a scheduled maintenance window.
1000/1500 Modular Smart Array rmware updating guide
15