HP StorageWorks 1000/1500 Modular Smart Array firmware updating guide (370881-002, June 2007)

Class
I
H/W Path
Driver
State
H/W Type
Description
______ _ _______________________ _______ _______ _________ ________________
ba
2
0/2
lba
CLAIMED BUS_NEXUS
Local PCI
Adapter (782)
fc
1
0/2/0/0
fcd
CLAIMED INTERFACE
HP 2Gb Dual Port
PCI/PCI-X Fibre
Channel Adapter
(Port 1)
/dev/fcd1
fcp
0
0/2/0/0.4
fcd_fcp
CLAIMED INTERFACE
FCP Domain
ext_bus 4
0/2/0/0.4.11.0.0
fcd_vbus
CLAIMED INTERFACE
target
8
0/2/0/0.4.11.0.0.1
tgt
CLAIMED DEVICE
disk
4
0/2/0/0.4.11.0.1.7
sdisk
CLAIMED MSA VOLUME
/dev/dsk/c4t1d7 /dev/rdsk/c4t1d7
target
9
0/2/0/0.4.11.0.0.2
tgt
CLAIMED DEVICE
disk
5
0/2/0/0.4.11.0.1.5
sdisk
CLAIMED MSA VOLUME
/dev/dsk/c4t2d5 /dev/rdsk/c4t2d5
.
.
.
ext_bus 5
0/2/0/0.4.11.255.0
fcd_vbus
CLAIMED INTERFACE
FCP Device
Interface
target
7
0/2/0/0.4.11.255.0.0
tgt
CLAIMED DEVICE
ctl 4
0/2/0/0.4.11.255.0.0.0
sctl
CLAIMED DEVICE
MSA
/dev/rscsi/c5t0d0
4. ObtainandrecordtheWorldWidePortNames(WWPN)oftheHBAandtheMSAcontroller:
a. To obtain the WWPN of the HBA in the server, use the fcmsutil command from HP-UX: (The
WWPNiscalledthePortWorldWideNameinHP-UX.):
Example command, using the sample information in Step 3:
fcmsutil /dev/fcd1
b. To obtain the WWPN of the MSA controller, use the show this_controller MSA CLI
command: (The WWPN is called the Reported Port ID in the CLI.):
Example command, using the sample information in Step 3:
show this_controller
c. Read the system displays and record the WWPN in the spaces provided in Table 6.
5. Download the rmware to the active controller by entering the SCU DOWNLOAD command:
NOTE:
To download new rmware to the controller, you must know the:
•Pathofthermware le, obtained in Step1.
(Example path: /tmp/scu/msav686b397.bin)
Device Special Filename of the controller, obtained in Step 3.
(Example DSF: /dev/rscsi/c5t0d0 )
1000/1500 Modular Smart Array rmware updating guide