HP StorageWorks 1000/1500 Modular Smart Array application note: Migrating from an active/passive single controller to active/active dual controllers in HP-UX environments (400677-002, October 2006)

Migrating from an active/passive single controller to active/active dual controllers in HP-UX environments 11
Verifying SAN connectivity
Step Description Check
1
For switch fabric SAN connectivity:
Log on to the switch management utility and verify that the switch fabric is set up
properly, including zoning.
From the MSA CLI, enter show this_controller to verify that this MSA array
controller is configured for switch fabric connectivity.
From the MSA CLI, enter show other_controller to verify that the other MSA
array controller is configured for switch fabric connectivity.
Example display:
CLI>show this_controller
Controller
MSA1500(c) Hewlett-Packard P56350A9IMN01Z Version 6.32 Build 1
Hardware 7
Component Enclosure.
Controller Identifier:
NODE_ID = 500508B3-00909AA0
SCSI_VERSION = SCSI-3
Supported Redundancy Mode:Active/Standby Asym-Active/Active
Current Redundancy Mode:Asym-Active/Active Active/Standby
Simulation DISABLED
Device Port SCSI address 7
Terminal speed for the CLI is set to 19200.
Host Port_1:
REPORTED PORT_ID 500508B3-00909AA9
PORT_1_TOPOLOGY = F_Port (Switch Fabric Enabled)
F
2
For direct connect SAN connectivity:
From the MSA CLI of the newly added controller:
Enter show this_controller_hard_address to determine if the MSA array
controller is configured for direct connect SAN connectivity.
Enter set this_controller_hard_address to enable hard addressing on
the array controller.
Example display when hard addressing is disabled:
CLI>show this_controller_hard_address
Hard Addressing is disabled.
Example display of enabling a hard address:
CLI>set this_controller_hard_address enable 10
Hard Addressing is enabled.
Loop ID=10, AL-PA=0xD5
Negotiated Two Gig
F