HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

3Updatingthecomponents
Perform the following procedures, as needed, to update system components:
Updating the operating system
Updating switch rmware
Updating HBA rmware
Upd ating SCSI hard drive rmware
Updating multipathing software
Updating HBA drivers, MPIO components, and the ACU
Updating MSA contro ller rmwar e
Updating the operating system
Obtain the nee ded les and installation instructions from the operating system vendor web site or the
HP IT Resource Center web site: h
ttp://www.itrc.hp.com.
CAUTION:
Operating system updates require one or more system restarts and should be performed during
scheduled m
aintenance time.
Updating switch rmware
Obtain the needed les and installation instructions from the switch vendor or HP SAN Infrastructure
web site:h
ttp://www.hp.com/go/san.
Updating HBA rmware
Obtain the ne eded les and installation instructions from the HP SAN Infrastructure web site:
h
ttp://www.hp.com/go/san.
NOTE:
SpecicversionsofHBArmware and HBA drivers are designed to work together. For more information,
see Determining which components to update and the MSA-specic compatibility guide on the Technical
Documentation page of each MSA web site.
Updatin
g SCSI hard drive rmware
SCSI har
ddrivermware updates are performed from the bootable P roLiant Firmware M aintenance C D
and are required only when the following message is displayed on the MSA controller LCD panel:
85 BAD DRIVE FRMWARE BOX <n> BAY <n>
CAUTION
:
This upd
ate procedure must be performed during a scheduled maintenance window.
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
15