HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

Using the MSA Flash Utility (Windows or Linux ProLiant server)
The MSA Flash Utility provides an easy-to-use graphical user interface for updating rmware on MSA
components, such as the controller and the fan module. In addition, congurations with attached MSA20
SATA storage enclosures can update rmware on the MSA20 controller and fan modules.
NOTE:
If the MSA is di
r ectly-connected to a NetWare, HP-UX, OpenVMS, or Tru64 UNIX server, y ou can
use this method to update the controller rmware by temporarily connecting the MSA to a Windows
or Linux ProLiant server and performing the update through the ProLiant server . The selected ProLiant
server must have an MSA-supported HBA installed. For a complete list of supported devices, see the
MSA compatibility guide on the Technical Documentation page of the appropriate MSA web site.
Depending on your environment and preference, the MSA Flash Utility can be run from a bootable
CD created from a downloaded ISO image or from les downloaded to the ser ver. As detailed in
the following sections, procedures to access the utility vary, based on your operating system and
online/ofine ash m ethod.
1. Access the Firmware Flash Utility:
If you are performing a rmware update using a bootable rmware CD:
Insert the CD created in Obtaining MSA support software or controller rmware into the
CD-ROM drive of the server.
Following the recommended procedures, power off the MSA.
Following recommended procedures, power off the selected ProLiant server.
Power on the MSA and wait (up to eight minutes) for the MSA to co mplete its startup routine.
Power on the server and wait for it to boot from the rmware CD and display the MSA
Utility screen.
Select Flash MSA Firmware and wait for the MSA Flash Utilit y to open.
If you are performing an update from rmware les copied to a temporary directory on the server:
Navigate to the directory on the server in which you copied the rmware les. For more
information, see Obtaining MSA support soft ware or controller rmwar e.
Locate and run the executable le that will install the MSA Flash Utility on the server:
In Windows environments, do uble-click the ash utility executable le to install the MSA
Flash Utility (example le: msa1500flash.msi. Then, double-click the MSA Flash
icon on the desktop.
In Linux environments, execute the downloaded rpm le to install the MSA Flash Utility
(example le and command: rpm -Uvh msa1500flash-6.86-2.i386.rpm.Then,
from a terminal running within an X Windows shell, enter msaflash and wait for the
MSA Flash Utility to open.
2. In the Firmware Flash Utility, click Find Devices.
After a few moments, all MSA c ontrollers visible to the server are displayed.
NOTE:
Depending on the detected MSAs and the contents of the rmware bundle, informational
pop-up messages may be displayed. Read these messages carefully and follow the
on-screen instructions.
22
Updating the components