HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

NOTE:
The following images reect updating a n MSA1500 in a Windows Server 2003
environment. Displays for the MSA1000 or for the Linux operating systems differ.
NOTE:
In dual-controller congurations, only the active controller (usually controller 1, the
front-right controller) is displayed and updated through the MSA Flash Utilit y. The other
controller is updated (cloned) when the MSA is restarted.
3. View the top-middle portion of the display and identify the components included in the Bundled
Firmware download, including:
•MSAcontrollerrmware version
•MSA20controllerrmware version
Fan control module rmware version
4. View the body of the window and identify the MSA controllers tha t were discovered. Look for the
following information:
MSA type (MSA1000 or MSA1500), serial number, and user-dened name
Currently installed version of MSA controller rmware ROM
Currently installed version of MSA20 controller rmware ROM
Currently installed version of fan control module rmware on each discovered MSA
5. In the displayed list of discovered controllers, select a controller to update.
6. Click an updating option:
Blink O n/Blink Off: Blink the LEDs on the selected MSA, its attached storage enclosures, and
the h a rd drives.
Recommended: Flash All Bundled Firmware on Selected MSA1500 and all at tached Devices:
Based on the rmware items included in the download, update these components on the MSA
and its attached enclosures.
Flash Ac tive/Standby Controller: Update the rmware on the selected MSA.
Flash All Attached MSA20: Update the rmware on any MSA20 storage enclosures a t tached
to the selected MSA.
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
23