HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

Class
I
H/W Path
Driver
State
H/W Type
Description
______ _ _______________________ _______ _______ _________ ________________
ba
2
0/2
lba
CLAIMED BUS_NEXUS
Local PCI
Adapter (782)
fc
1
0/2/0/0
fcd
CLAIMED INTERFACE
HP 2Gb Dual Port
PCI/PCI-X Fibre
Channel Adapter
(Port 1)
/dev/fcd1
fcp
0
0/2/0/0.4
fcd_fcp
CLAIMED INTERFACE
FCP Domain
ext_bus 4
0/2/0/0.4.11.0.0
fcd_vbus
CLAIMED INTERFACE
target
8
0/2/0/0.4.11.0.0.1
tgt
CLAIMED DEVICE
disk
4
0/2/0/0.4.11.0.1.7
sdisk
CLAIMED MSA VOLUME
/dev/dsk/c4t1d7 /dev/rdsk/c4t1d7
target
9
0/2/0/0.4.11.0.0.2
tgt
CLAIMED DEVICE
disk
5
0/2/0/0.4.11.0.1.5
sdisk
CLAIMED MSA VOLUME
/dev/dsk/c4t2d5 /dev/rdsk/c4t2d5
.
.
.
ext_bus 5
0/2/0/0.4.11.255.0
fcd_vbus
CLAIMED INTERFACE
FCP Device
Interface
target
7
0/2/0/0.4.11.255.0.0
tgt
CLAIMED DEVICE
ctl 4
0/2/0/0.4.11.255.0.0.0
sctl
CLAIMED DEVICE
MSA
/dev/rscsi/c5t0d0
4. ObtainandrecordtheWorldWidePortNames(WWPN)oftheHBAandtheMSAcontroller:
a. To obtain the WWPN of the HBA in the server, use the fcmsutil command from HP-UX: (The
WWPNiscalledthePortWorldWideNameinHP-UX.):
Example comm and, using the sample information in Step 3:
fcmsutil /dev/fcd1
b. To obtain the WWPN of the MSA controller, use the show this_controller MSA CLI
command: (The W W PN is called the Reported Port ID in the CLI.):
Example comm and, using the sample information in Step 3:
show this_controller
c. Read the system displays and record the W W P N in the spaces provided in Table 6.
5. Download the rmware to the active controller by entering the SCU DOWNLOAD command:
NOTE:
To download new rmware to the controller, you must know the:
•Pathofthermware le, obtained in Step1.
(Example path: /tmp/scu/msav686b397.bin)
DeviceSpecialFilenameofthecontroller,obtainedinStep 3.
(Example DSF: /dev/rscsi/c5t0d0 )
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide