HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

# scu -f /dev/rscsi/c5t0d0 show inquiry
Inquiry Informa
tion:
Peripheral Devi
ce Type:
Peripheral Qual
ifier:
Device Type Modi
fier:
Removable Media
:
ANSI Version:
ECMA Version:
ISO Version:
Response Data Fo
rmat:
Terminate I/O Pr
ocess:
Additional Leng
th:
Reserved (byte 5
):
Soft Reset Suppo
rt:
Target Transfer
Disable:
Linked Command S
upport:
Synchronous Dat
a Transfers:
Support for 16 Bi
t Transfers:
Support for 32 Bi
t Transfers:
Relative Addres
sing Support:
Vendor Identifi
cation:
Firmware Revisi
on Level:
Vendor Specific
Data:
Oxc <Array Controller>
0 <Peripheral Device Connected>
0
No
<Complies to ANSI X3.351-200x, SPC-2>
0
0
2 <SCSI-2)
No
247
0x80
No
No
No
No
No
No
No
MSA1xxx
6.86
35 30 44 39 49 50 30 33 56 00 00
10. Before resuming I/O a c cess to the MSA , verify that the MSA and its storage arrays are online.
Using the MSA_Util (OpenVMS)
1. Obtain the rmware les as instructed in O btaining MSA suppor t software or controller rmware.
NOTE:
The rmware le must be copied to a local disk on the OpenVMS system. The MSA cannot
be updated from a rmware CD.
2. ObtaintheCurrentFibreSCSIECOKitforyourversionofOpenVMSfromtheHPITResource
Center at h
ttp://www.itrc.hp.com.
For existing OpenVMS installations:
Install the Fibre SCSI ECO kit on all of the system disks (of all OpenVMS systems in the
SAN), and then restart all updated servers. For instructions, see the documentation that
came with the Fibre SCSI ECO kit.
For new OpenVMS installations:
Create a L UN on the MSA, and then assign a unique identier to the LUN. For instructions,
see the MSA1000/1500 Command Line Interface User Guide.
Install OpenVMS. For instructions, see the Op enVMS documents associated with the version
being installed.
Install the Fibre SCSI ECO kit on all system disks and restart all updated servers. For
instructions, see the documentation that came with the Fibre SCSI ECO kit.
3. Verify that the MSA is connected to the SAN.
4. Verify that each MSA c ontroller has been assigned a unique identier. For instructions, see the
MSA1000/1500 Command Line Interface User Guide.
5. Stop all I/O to the MSA.
6. IftheMSAcontrollerortheuser-dened ID was added after OpenVMS was booted, issue the
following commands:
$ RUN SYS$SYSTEM:SYSMAN
SYSMAN> IO AUTOCONFIGURE
SYSMAN> EXIT
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
29