HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

7. Enter the following command to open the MSA_UTIL rmware ash program:
RUN SYS$ETC:MSA_UTIL
8. Enter the show controller command to see a list of MSA controllers on the SAN:
Example com mand and response:
MSA> SHOW CONTROLLER/BRIEF
A default controller is not set. All matching controllers displayed:
Controller: $1$GGA400:
MSA1xxx (C) COMPAQ P56350B9IMX025 Software 3.36
NODE_ID = 500805f3-0001b290
Controller Identifier: 400
Current Redundancy mode: Active/Standby
Current Role: Active
Controller: $1$GGA401:
Controller Identifier: 401
MSA1xxx (C) COMPAQ P56350B9IN20HW Software 3.36
NODE_ID = 500805f3-0001b290
Current Redundancy mode: Active/Standby
Current Role: Standby
9. Enter the set controller command to indicate the controller to be ashed:
Example command and response, using the sample information in Step 8:
MSA> SET CONTROLLER $1$GGA400.
10. Enter the flash firmware command to begin the update:
Example command and response, using the sample information in Step 1:
MSA> FLASH FIRMWARE MSAV686B272.BIN
Sending Flash Command. Please wait.
New firmware will be loaded when THIS_CONTROLLER is reset.
NOTE:
The MSA displays the message FIRMWARE FLASH STARTED when it starts the download
and FIRMWARE FLASH DONE when the download is complete.
11. After the controller displays FIRMWARE FLASH DONE, do one of the following:
If you have one MSA with a sing le controller, the rmware update procedure is complete.
Proceed to Step 12.
If you have one MSA with dual controllers, you must update the rmware on the second
controller. Repeat Step 8 through Step 10to update the rmware on that controller .
If you have multiple MSAs, repeat Step 8 through Step 10 foreachcontrollerineachMSA.
12. Enter the following command to exit the update utility:
MSA> EXIT
13. After all MSA controllers have be en updated and the controller displays FIRMWARE FLASH DONE,
power-cycle the MSA by doing the following:
a. Remove power from the MSA.
b. After a few moments, reapply power to the MSA.
After the MSA completes its start up routine, the STARTUP COMPLETE message is displayed:
14. To verify that the rmware was updated, use the following commands:
$ RUN SYS$$ETC:MSA_UTIL
MSA> SHOW CONTROLLER/BRIEF
A default controller is not set. All matching controllers displayed:
30
Updating the components