HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

Controller: $1$GGA401:
MSA1xxx (C) COMPAQ P56350B9IN20HW Software x.xx
Controller Identifier: 401
NODE_ID = 500805f3-0001b290
Current Redundancy mode: Active/Standby
Current Role: Standby
Controller: $1$GGA400:
MSA1xxx (C) COMPAQ P56350B9IMX025 Software x.xx
Controller Identifier: 400
NODE_ID = 500805f3-0001b290
Current Redundancy mode: Active/Standby
Current Role: Active
15. Before resuming I/O access to the MSA, verify that the MSA and its storage arrays are online.
Using the SC SI CAM Utility (Tru64 UNIX)
NOTE:
If you are updating the MSA controller rmware to version 4.24 or later and you plan to install version
5.1A on your AlphaServer, the following sequence is required:
Update the MSA co
ntroller rmware to version 4.24 or later using the factory installed version
5.1B system disk.
Install version 5.1A on your AlphaServer.
NOTE:
If you are updating the MSA controller rmware to version 4.24 or later and your server has one
CD-ROM drive and no diskette drive, use one of the following recommended processes:
Install the Tru64 UNIX operating system on to a local disk.
Update the MSA controller rmware.
Install or back up the Tru64 U NIX operating system onto an MSA logical unit.
—OR—
Connect to another AlphaServer that supports rmware updates.
Update the MSA controller rmware.
Reconnect to the AlphaServer.
Install the Tru64 UNIX operating system onto an MSA logical unit.
NOTE:
The following procedure uses an example conguration of one MSA with two controllers. Use information
from your conguration to install the rmware.
1. Obtain the rmware les as instructed in O btaining MSA suppor t software or controller rmware.
2. From Tru64, enter the following comm a nd to determine the hardware ID (HWID) of each MSA:
> hwmgr view device | grep MSA | grep -v VOLUME
After a few moments, the following information is displayed:
HWID: Device Name Mfg Model Location :
115 /dev/cport/scp0 MSA CONTROLLER bus-0-targ-0-lun-0
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
31