HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

Delaying for 120 seconds while firmware is saved, please be
patient... 120
The utility counts down from 120 seconds, returning to the scu prompt when the time delay is
complete.
CAUTION:
Do not restart the server.
NOTE:
The MSA controller displays the message FIRMWARE FLASH STARTED when it
starts the download, and FIRMWARE FLASH DONE when the download is complete.
6. AftertheMSAcontrollerdisplaysFIRMWARE FLASH DONE, do one of the following:
If you have one MSA with a single-controller, the rmware update is complete. Proceed
to Step 7.
If you have one MSA with dual controllers, you must update the rmware on the second
controller. Repeat Step 5 for the second controller.
If you have mul
tiple MSA, repeat Step 5for each controller in each MSA.
7. After the rmware has been updated on all MSA controllers, exit the SCU by entering:
scu> exit
8. After the rm
ware has been updated on all MSA c ontrollers, restart your system using the following
sequence:
a. Shut down the operating system on each server.
b. Remove power from each MSA.
c. After a few m
oments, reapply power to the MSA.
When the MSA completes its startup routine, the STARTUP COMPLETE message is displayed.
d. After the MSA has completed its startup routine, restart each AlphaServer.
9. Verify that the c ontroller rmware was updated by entering:
scu> show e
dt | grep MSA | grep -v VOLUME
0 0 0 RAID !ANSI MSA CONTROLLER 6.86 n
6 0 0 RAID !ANSI MSA CONTROLLER 6.86 n
7 0 0 RAID !A
NSI MSA CONTROLLER 6.86 n
8 0 0 RAID !ANSI MSA CONTROLLER 6.86 n
10. Before resuming I/O access to the MSA, from the server, verify that the MSA and its storage a rrays
are online
.
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
33