HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

c. Click Send.
A 1K Xmodem status window is displayed.
NOTE:
The MSA controller displays the message FIRMWARE FLASH STARTED when it starts the
download, a nd FIRMWARE FLASH DONE when the download is complete.
6. Wait for a completion message to be displayed.
7. Restart the MSA—Newly downloaded rmware cannot be accessed until the MSA is restarted.
For ofine downloads, manually power cycle the MSA by pressing and releasing the
power/standby button on the front of the MSA.
For online downloads, wait for the MSA controller to automatically restart.
NOTE:
In dual-controller congurations, rmware on the two contr ollers is compared each time
the MSA chassis is restarted. If the v e rsions are mismatched, the system prompts to clone
the rmware on the controller with the latest version over to the controller with the earlier
version rmware. The following message is displayed on the LCD p anel of the c ontroller
with the earlier rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
8. Before resuming I/O access to the MSA, verify that the MSA and its storage arrays are online.
36
Updating the components