HP StorageWorks 1000/1500 Modular Smart Array application note: Migrating to active/active controllers in NetWare environments (434884-001, October 2006)

8
Activating the multi-pathing feature
MSA active/active controllers use the Native MPIO provided by Novell for Multi-pathing. To activate the
multi-pathing feature, the configuration file startup.ncf must be modified by doing the following:
NOTE: The Native MPIO solution can co-exist with HP Secure Path for NetWare even with the above
changes.
If the Secure Path for NetWare driver needs to be removed, follow these steps:
Verifying multi-path options
To verify the multi-path options, enter: list failover devices
Verify that all paths are seen by the hosts.
Step Description Check
1
Edit c:\nwserver\startup.ncf
F
2
Add the following as the first line of the file:
SET MULTI-PATH SUPPORT = ON
F
3
Modify the line:
LOAD SCSIHD.CDM
to
LOAD SCSIHD.CDM /AEN
F
4
QL2x00.HAM drivers should be loaded with the following options:
LOAD QL2X00.HAM SLOT= n /LUNS /ALLPATHS /PORTNAMES
(where n is the slot number)
F
Step Description Check
1
Follow the instructions given in the Secure Path 3.0C NetWare user guide.
F
2
Comment out the entry:
#LOAD HPQSP.CDM from startup.ncf
F
3
Edit SYS:\SYSTEM\AUTOEXEC.NCF and comment out the following entries:
#LOAD HPQSPAGT.NLM
#LOAD HPQSPAHW.NLM
F