HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

User input messa
ges
User input messages indicate that the system has encountered a situation that allows user input. The user
can select from a number of choices. If the user does not select one of the choices in a set amount of
time, the system selects the default setting. These user input messages only occur during system power
on, and not dur
ing runtime.
The array cont
roller Fault LED to the left of the LCD panel display window blinks on and off when a user
input message is currently being viewed and is available for input. If input is not provided within the
time-out period, the message remains, but the LED stops blinking.
LCD message descriptions
NOTE:
Some messages may specify a box number. For the MSA1500 and MSA1510i, the following box
numbers are predened:
Predened box number Physical connection to MSA SCSI I/O module
Box 1
PortAofSCSII/Omodule1(Bus0)
nl
(right port on the right-most SCSI I/O module)
Box 2
PortAofSCSII/Omodule2(Bus1)
Box 3
Port A of SCSI
I/O module 3 (Bus 2)
Box 4
PortAofSCSII/Omodule4(Bus3)
Box 5
Port B of SCSI I/O module 1 (Bus 0)
Box 6
Port B of SCSI
I/O module 2 (Bus 1)
Box 7
Port B of SCSI I/O module 3 (Bus 2)
Box 8
Port B of SCSI I/O module 4 (Bus 3)
nl
(left port on the optional left-most SCSI I/O module)
The following table contains the dened messages and their components:
Table 7 LCD message descriptions
Message Type
Description Action
00 ARRAY
CONTROLLER
FIRMWARE VER
<version>
Informati
onal
Displays th
ecurrentversionof
rmware ru
nning on the array
controlle
r.
01 MSA STARTUP
COMPLETE
Informational
The array controller has completed
itspoweronsequenceandisnow
operational.
1510i Modular Smart Array installation and user guide
107