HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
31 I2C WRITE
FAILURE <I2C
device name>
Error
The MSA has a number of internal
devices that are accessed via an
I2C hardware bus. One of these
devices failed when attempting to
write to it. Certain I2C devices are
considered critical and will result
in a failure of the array controller,
while others may result in some
loss of functionality (such as lost
display messages).
If the issue persists, contact HP
support.
32 CHASSIS
NVRAM
CONTENTS C
ORRUPTED
Error
The MSA has n
on-volatile memory
on it that co
ntains required
informati
on, which is needed to
operate. T
his non-volatile memory
appears to
be corrupted and the
informat
ion is not valid. The MSA
cannot co
ntinue to operate and
will halt
.
Contact HP
support.
40 INITIALIZING
REDUNDANCY SUPPORT
Informational
Two array controllers are installed,
and they are attempting to enter
redundant mode.
41 REDUNDANCY
ACTIVE ACTIVE
CONTROLLER
Informational
Two array controllers are installed,
and they are now in redundant
mode.Thiscontrollerisactiveand
can access congured volumes on
the MSA.
42 RE
DUNDANCY
ACTI
VE STANDBY
CON
TROLLER
Informational
Two array controllers are installed,
and they are now in redundant
mode. This controller is in standby
and cannot access congured
volumes on the MSA. This controller
canbemadeactiveifthecurrent
active controller fails, assuming
all redundant components are
installed (I/O module, cables, and
multipathing software).
43 REDUNDANCY
FAILED HARDWARE
FAILURE
Error
While either attempting to enter
redundant mode or already
operating in redundant mode, one
of the two installed array controllers
encountered a hardware failure
on the communication channel
between the two array controllers.
Redundancy is disabled at this
time.
If the MSA is currently involved
in host I/O, remove the standby
array controller, wait 10 seconds,
and then reinsert it, ensuring that it
is fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
PowerofftheMSA,removeboth
array controllers, and reinsert
them, ensuring they are fully
seated in the chassis.