HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
49 REDUNDANCY
FAILED FIRMWARE
LOCKUP
Error
While either attempting to enter
redundant mode or already
operating in redundant mode, one
of the array controllers encountered
a critical condition resulting in a
rmware lockup. Redundancy is
disabled at this time.
If the MSA is currently involved
in host I/O, remove the standby
array controller, wait 10 seconds,
and then reinsert it, ensuring that it
is fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
PowerofftheMSA,removeboth
array controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist, contact
HP support.
50 REDUND
ANCY
FAILED OU
TOF
MEMORY
Error
While either attempting to enter
redundant mode or already
operating in redundant mode,
one of the array controllers failed
to allocate required memory.
Redundancy is disabled at this
time.
If the MSA is
currently involved
in host I/O,
remove the standby
array cont
roller, wait 10 seconds,
and then re
insert it ensuring that it
is fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
PowerofftheMSA,removeboth
array controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist, contact
HP support.
51 REDUNDANCY
FAILED I/O REQUEST
ERROR
Error
While either attempting to enter
redundant mode or already
operating in redundant mode, one
of the array controllers encountered
an error while sending I/O
between the two array controllers
over the communication channel
between them. Redundancy is
disabled at this time.
If the MSA is currently involved
in host I/O, remove the standby
array controller, wait 10 seconds,
and then reinsert it, ensuring that it
is fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
PowerofftheMSA,removeboth
array controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist, contact
HP support.
52 REDUNDANCY
FAILED PCI BUS
ERROR
Error
While either attempting to enter
redundant mode or already
operating in redundant mode,
one of the array controllers
encountered a PCI bus error on
the communication channel used
between the two array controllers.
Redundancy is disabled at this
time.
If the MSA is currently involved
in host I/O, remove the standby
array controller, wait 10 seconds,
and then reinsert it, ensuring that it
is fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
PowerofftheMSA,removeboth
array controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist, contact
HP support.
53 REDUNDANCY
FAILED NO SECOND
CONTROLLER
Error
While operating in redundant
mode, one of the two installed
array controllers was removed.
Redundancy is disabled at this
time.
Reinsert the missing array
controller, ensuring that it is fully
seated in the chassis.
1510i Modular Smart Array installation and user guide
11 3