HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
66 CACHE HARDWARE
FAILED AND
DISABLED
Error
The cache memory has
experienced a hardware failure.
If the failure has occurred on the
standby array controller, remove
the standby array controller,
replace the cache modules, wait
10 seconds, and then reinsert the
array controller, ensuring that it is
fully seated in the chassis.
If the failure has occurred on the
active array controller, wait until
downtime is available. Power
off the MSA, remove the array
controller, replace the cache
modules, and reinsert the array
controller, ensuring it is fully seated
in the chassis.
Should the issue persist, contact
HP support.
67 CACHE HARDWARE
TEMPORARILY
DISABLED
Informational
The cache memory hardware
has temporarily been disabled,
typically because the battery is not
charged or a capacity expansion
operation is occurring. The cache
automatically enabled once the
condition has been corrected.
68 OBSOLETE CACHE
DATA DELETED
Informational
Old data that no longer belongs
to any current congured volumes
was found in the cache memory
at power up. This data has been
deleted. This typically happens
ifcachemodulesaremoved
between array controllers.
69 CACHE BATTERIES
LOW, RECHARGING
Informational
Thebatteriesonthecachemodule
are low and are being recharged.
70 CACHE DISABLED
NO CONFIGURATION
Informational
The cache has not been congured
and is disabled. The cache is
congured using the Storage
Management Utility (SMU) or
MS
A Command Line Interface
(M
SA-CLI).
1510i Modular Smart Array installation and user guide
115