HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
88 NON-HP DRIVE
BOX #<n>, BAY <n>
Informational
An unsupported hard drive is
located in the indicated bay of the
storage enclosure.
89 INVALID CONFIG
BOX #<n>, BAY <n>
Error
The indicated hard drive contains
unrecognized conguration
information f
rom another system
and therefor
ewillnotbeused.
Replace the indicated hard drive.
100 VOLUME #<n>
STATE OK
Informational
The congured volume has
returned to its normal operating
state. This typically occurs after a
rebuild operation has completed.
101 VOLUME #<n>
STATE FAILED
Error
The congured volume has been
failed because too many SCSI
hard drives that it is composed of
have failed, exceeding the fault
tolerance level. The data on the
congured volume is no longer
available. There is a risk of data
loss.
Replace the failed hard drives as
soon as possible. If necessary,
restore data from backup.
102 VOLUME #<n>
STATE INTERIM
RECOVERY
Informational
The array controller has failed one
or more SCSI hard drives that the
congured volume is composed
of. No d
ata loss has occurred
becaus
e fault tolerance is allowing
the dat
a to be recovered.
Replace the failed hard drives as
soon as possible.
103 VOLUME #<n>
STATE REBUILDING
Informational
The congured volume is rebuilding
data on a SCSI drive that replaced
a previously failed drive.
104 VOLUME #<n>
STATE DISABLED
Error
The congured volume has been
disabled because too many of
theSCSIharddrivesthatitis
composed of are missing.
Power off the MSA and all attached
external storage enclosures.
Unplug and reinsert all SCSI hard
drives, ensuring they are fully
seated in their bays. Check the
cables connecting the MSA to
any attached storage enclosures.
Power on the attached storage
enclosures and then the MSA.
105 VOLUME #<n>
STATE EXPANSION
ACTIVE
Informational
The congured volume is currently
pe
rforming a volume expansion
op
eration.
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational
The congured volume is waiting
to start rebuilding data on a SCSI
drive that replaces a previously
failed drive. The rebuild may not
have started yet because the array
controller is already performing
a rebuild on another congured
volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational
The congured volume is waiting
to start a volume expansion
operation. The expansion may
havenotstartedyetbecause
another congured volume is
undergoing expansion or a rebuild
is occurring on the congured
volume.
118
MSA controller LCD panel message descriptions