HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
150 BEACON ON
Informational
The LEDs on the MSA and all
connectedharddrivesareblinking
because that array controller
was selected for identication
or conguration in a host-based
application such as the ACU or
SMU.
151 BEACON O
FF
Informational
The LEDs on the MSA and all
connectedharddrivesareno
longer blinking because the
host-based application is no longer
identifyi
ng or conguring this
MSA.
201 ARRAY
CONTROLLER
TEMPERATURE OK
Informational
The temperature sensor on the
array controller indicates that the
temperature that was previously
exceeding the normal operating
range is now back within the
range.
202 ARRAY
CONTROLLER
OVERHEATING
Error
The temperature sensor on the
array controller indicates that
the array controller is starting
to exceed the normal operating
range.
Check all MSA fans and ensure
they are operating. Any failed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the airow and cooling
ability of the MSA.
203 ARRAY
CONTROLLER
OVERHEATED
Error
The
temperature sensor on the
arr
ay controller indicates that the
ar
ray controller has exceeded the
sa
fe operating range.
The M
SA should be powered
off a
ssoonaspossibletoavoid
hard
ware failure.
Chec
kallMSAfansandensure
the
yareoperating. Anyfailed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the airow and cooling
a
bility of the MSA.
204 ARRAY
CONTROLLER
DISABLED
Error
The array controller has been
disabled due to a redundancy
failure.
Remove the disabled array
controller, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
If the issue persists, contact HP
support.
205 ARRAY
CONTROLLER
RESTARTING
Informational
The array controller has completed
rmware cloning and is being
restarted automatically.
300 RECOVERY ROM
AUTOFLASH STARTED
Informational
The array controller has detected
that the rmware's backup
recovery ROM image is invalid
and is copying the current active
rmware image into the backup
recovery ROM.
1510i Modular Smart Array installation and user guide