HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
301 RECOVERY ROM
AUTOFLASH DONE
Informational
The array controller has successfully
completed the process of copying
the current active rmware image
into the backup recovery ROM.
302 RECOVERY R
OM
AUTOFLASH FA
ILED
Error
The array controller failed to copy
the current active rmware image
into the backup recovery ROM.
Recovery ROM support is disabled.
Remove the fail
ing array controller,
wait 10 second
s, and then reinsert
the array cont
roller, ensuring that
it is fully seated in the chassis.
The ROM autoash process is
attempted again.
Should the issue persist, contact
HP support.
303 ROM CLONING
STARTED
Informational
Indicates that the two array
controllers in the MSA do not
havethesameversionofrmware
on them. Therefore, one array
controller's version of the rmware
is copied on to the other array
controller. Both controllers must
be running the same version of
rmware in order for controller
redundancy to operate. If both
array controllers are in the
power-on sequence, the most
recent version of rmware is used.
If one array controller has already
completed the power-on sequence
and is now active, its version of
rmware is used even if less recent.
304 ROM CLONING
DONE
Informational
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA have nished
copying one array controller's
version of rmware to the other
array controller. Both controllers
must be running the same version
of rmware in order for controller
redundancy to operate.
305 ROM CLONING
FAILED
Error
In dual-controller MSA only,
this indicates that the two array
controllers in an MSA failed to
copy one array controller's version
of rmware to the other array
controller. Both controllers must
be running the same version of
rmware in order for controller
redundancy to operate.
R
emove the standby array
c
ontroller, wait 10 seconds, and
then reinsert the array controller
ensuring that it is fully seated in the
chassis. The ROM cloning process
is attempted again.
If the issue persists, contact HP
support.
306 FIRMWARE FLASH
STARTED
Informational
The array controller in the MSA has
started the rmware ash process.
Do not turn off power to the system
until it has completed. This could
take several minutes.
122
MSA controller LCD panel message descriptions