HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
307 FIRMWARE FLASH
DONE
Informational
The array controller in the MSA
has completed the rmware ash
process. It is now safe to restart
the MSA and begin using the
new rmware. In dual-controller
congurations, the new rmware
is cloned onto the other controller
during the startup routine.
308 FIRMWAR
E FLASH
FAILED
Error
The array co
ntroller in the MSA has
failed the
rmware ash process.
Attempt the ash process again.
If the issue
persists, contact HP
support.
309 EMU FLASH
STARTED
Informational
The EMU has started the rmware
ash process. Do not turn off the
power to the system until it has
completed. This could take ve
minutes.
310 EMU FLASH DONE
Informational
The EMU has completed the
rmware ash process. It is now
safe to turn off power to the system.
311 EMU FL
ASH
FAILED
Error
The EMU has failed the rmware
ash process.
Attempt the ash process again.
If the iss
ue persists, contact HP
support
.
312 FIRMWARE FLASH
STARTED ON BOX <n>
Informational
A rmware ash operation has
startedonanattachedstorage
enclosure.
313 FIRMWARE FLASH
DONE ON BOX <n>
Informational
A rmware ash operation has
completedonanattachedstorage
enclosure.
Restart the storage enclosure to
enable the new rmware.
314 FIRMWARE FLASH
FAILED ON BOX <n>
Error
A rmware ash operation has
failed on an attached storage
enclosure.
Attemp
ttheash process again.
If the issue persists, contact HP
support.
315 ISCSI MODULE
FLASH STARTED
Informational
Indicates that the array controller
has detected out-of-date rmware
on the iSCSI daughter board and
is updating the rmware. Do not
turn off power to the MSA until it
hascompleted. Thiscouldtake
several minutes.
316 ISCSI MODULE
FLASH DONE
Informational
Indicates that the array controller
has completed updating the
rmware on the iSCSI daughter
board. Restart the MSA to activate
the new rmware.
Restart the MSA to activate the
new iSCSI rmware before using
iSCSI functionality.
3
17 ISCSI MODULE
F
LASH FAILED
Error
Indicates that the array controller
was unable to update the rmware
on the iSCSI daughter board.
R
etry the operation. Contact HP
s
upport if the problem persists.
318 FAN FLASH
STARTED ON BOX
#<n>
Informational
Indicates that the array controller
has detected out-of-date rmware
on a fan module in the indicated
storage enclosure and is updating
the rmware. Do not turn off power
to the MSA until it has completed.
This could take several minutes.
1510i Modular Smart Array installation and user guide