406 STORAGE BOX
#<n> OVERHEATING
Error
The temperature in the specied
storage enclosure is starting to
exceed the normal operating
range.
Check all fans and ensure they are
operating. Any failed fans should
be replaced. Ensure that there is a
module or blanking panel (cover
plate) in all MSA chassis bays and
slots. Empty bays affect the airow
and cooling ability of the MSA.
407 STORAGE BOX
#<n> OVERHEATED
Error
The temperature in the specied
storage enclosure has exceeded
thesafeoperatingrange.
The MSA should be powered off as
soon as possible and immediately
after that, the enclosure should be
powered off, to avoid hardware
failure.
Check all MSA fans and ensure
they are operating. Any failed
fan should
be replaced. Ensure
that there
is a module or blanking
panel (co
ver plate) in all MSA
chassis b
ays and slots. Empty
bays affe
ct the airow and cooling
ability of the MSA.
408 STORAGE BOX
#<n> POWER SUPPLY
OK
Informational
Thepowersupplyinthespecied
storage enclosure that was
previously marked as failed or
degraded is now operating
normally.
409 STORAGE BOX
#<n> POWER SUPPLY
FAILED
Error
A power supply in the specied
storage enclosure has failed.
Check all power supplies to ensure
they are operating. Replace any
failed power supplies.
410 STORAGE BOX
#<n> POWER SUPPLY
ADDED
Informational
A power supply in the specied
storage enclosure has been added.
411 STORAGE BOX
#<n> POWER SUPPLY
REMOVED
Informational
A power supply in the specied
storage enclosure has been
removed.
412 STORAGE BOX
#<n> EMU NOT
RESPONDING
Error
An EMU in the specied storage
enclosure is not responding to
commands.
Make sure the storage box is
powered on. Ensure all cables are
connected securely. Power off the
MSA and the storage enclosure.
Then reapply power to the storage
box and then the MSA.
If the issue persists, contact HP
support.
413 STORAGE BOX
#<n> EMU VERSION
<version>
Informational
Th
eversionofrmware running on
th
eEMU.Thisisonlydisplayed
f
or the internal EMU of the MSA
c
hassis. It is not displayed for
e
xternally connected storage
boxes.
414 STORAGE BOX
HOT REMOVED
Informational
An external storage enclosure has
been hot removed from the back
of the MSA.
415 STORAGE BOX
HOT ADDED
Informational
An external storage enclosure has
been hot added to the back of the
MSA.