HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
450 INVALID SCSI
CABLING BOX #<n>
Error
The MSA has detected an external
storage enclosure that is cabled
incorrectly.
Verify that the external storage
enclosures are connected properly
to the MSA. For more information,
see the MSA installation guide.
500 INITIALIZING
PCI SUBSYSTEM
Informational
The array cont
roller's PCI subsystem
is being initi
alized as part of the
power up seque
nce.
501 PCI SUBSYSTEM
HARDWARE FAILURE
Error
The array controller's PCI subsystem
has encountered a critical error
during the power-up sequence.
Remove the failed array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that it
is fully seated in the chassis.
If the issue persists, contact HP
support.
502 PCI BRIDGE
ASIC SELF TEST
FAILURE
Error
The array controller's PCI bridge
ASIC has encountered a critical
error during the power-up
sequence.
Remove the failed array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that it
is fully seated in the chassis.
If the issue persists, contact HP
support.
512 ECC CO
RRECTED
MEMORY ER
ROR SEEN
Error
The array controller has detected
an uncorrectable ECC error in the
data cache memory.
Contact H
P support.
513 UNCORRECTED
ECC MEMORY ERROR
SEEN
Error
The array controller has detected
an uncorrectable error in the ECC
memory on the memory cache
board.
Remove the failed array controller
and replace the memory cache
board with a new one.
518 PERSISTENT MEM
ENABLED
Informational
Global variables such as system
prompts and prole information
remain persistent in cache over
power cycles of the system. This
message is displayed each time
the MSA is powered on.
519 P
ERSISTENT MEM
DISA
BLED
Informational
Pers
istent memory data has not
been
successfully initialized.
Some
conguration data may not
be av
ailable.
520 UNKNOWN I/O
MODULE DETECTED
Error
The MSA cannot determine the
type of I/O module installed in the
bay.
Do the following:
1. Remove power from any
external storage enclosures.
2. Remove power from the MSA.
3. Reseat all I/O modules.
4. Applypowertoanyexternal
storage enclosures.
5. Apply power to the MSA.
6. Verify that the MSA has
the latest version rmware
installed.
Should the issue persist, contact
HP support.
521 ISCSI PARAM
LOAD ERROR
Error
An error occurred while
programming iSCSI conguration
to the iSCSI hardware.
Contact HP support if the problem
persists.
126
MSA controller LCD panel message descriptions