HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
522 INITIALIZING
ISCSI SUBSYSTEM
Informational
The iSCSI subsystem is being
initialized as part of the power-on
sequence.
523 LOADING ISCSI
PARAMS
Informational
The iSCSI conguration is being
loaded into the iSCSI hardware as
part of the power-on sequence.
524 ISCSI MODULE
HARDWARE FAILURE
Error
The array controller has detected
a hardware failure in the iSCSI
daughter board.
Contact HP support.
525 ISCSI MODULE
BIST FAILED
Error
The iSCSI daughter board has
detected a failure during its Built
In Self Test (BIST).
Contact HP support.
526 ETHERNET
MODULE DETECTED
Informational
A 2-Port Et
hernet iSCSI module has
been inser
ted or detected during
POST.
527 ETHERNET
MODULE MISSING
Error
No 2-Port Ethernet iSCSI
module was detected during
POST. Network connectivity is
unavailable.
Inserta2-PortEthernetiSCSI
module into the appropriate slot in
the rear of the chassis.
528 ETHERNET
MODULE INVALID
Error
The module in the Ethernet module
bay is not a valid 2-Port Ethernet
iSCSI module, or the module has
failed.
Verify that the module is inserted
properly into the bay. If the
problem persists, replace the
module.
600 INITIALIZING
TARGET-BASED MGMT
Informational
The Tar
get-Based Management
subsys
tem is being initialized as
part of the power on sequence.
601 PORT <n> LINK
FAILURE
Error
TheMSAhasdetectedalink
failure on the indicated GBE port.
Checkthenetworkcableattached
to the port.
602 PORT <n> LINK
OK <speed> Mb/s
Informational
The MSA has detected an active
link on the indicated GBE port.
603 P
ORT <n> IP
<ip
>
Informational
The m
anagement IP address on the
indi
cated port has been changed,
and
the new address is displayed
for
user reference.
604 PORT <n> DHCP
FAILED
Error
The MSA has failed to obtain an IP
address for the management port
via DHCP, and will fall back to
zeroconf IP address.
Check that a DHCP server exists
on your network, or recongure
Target-Based Management to use
a static IP address.
605 MANAGEMENT
PORT <n> ENABLED
Informational
The MSA has enabled
management access through
the indicated port as part of the
poweronsequenceorduetoa
hardware failure on the congured
port.
606 MANAGEMENT
PORT <n> DISABLED
Informational
The MSA has disabled
management access through
the indicated port.
607 NO MANAGEMENT
HARDWARE FOUND
Error
The array controller is unable
to locate any Ethernet hardware
that can be used to provide
management access. Target-Based
Management functionality is
disabled.
Contact HP support.
1510i Modular Smart Array installation and user guide