HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

cache hardware enabled,114
cache hardware temporarily disabled,115
cache module size,114
chassis nvram contents corrupted,111
clone rmware,109
cloning refused system halted,109
congured volumes,119
controller too old not supported,109
critical lockup detected,108
drive failure box, bay,117
drive hot added box, bay,117
drive hot removed box, bay,117
drive position change detected,117
drive position change invalid,117
dual cache module size mismatch,114
ecc corrected memory error seen,126
EMU ash done,123
EMU ash failed,123
EMU ash started,123
enable volume,108
enable volumes,108
rmware ash done,123
rmware ash failed,109
rmware ash started,122
rmware version,107
FW version is not supported,110
initializing PCI subsystem,126
initializing SCSI devices,110
initializing SCSI subsystem,110
invalid SCSI cabling,126
new volume(s) detected,120
nocachemodulefound,114
no volumes detected,120
non-Compaq drive,118
obsolete cache data deleted,115
online upgrade complete,109
online upgrade ashing done,109
online upgrade ashing failed,109
online upgrade
ashing rmware,109
online upgrade ashing started,109
online upgrade incomplete,110
online upgrade redundancy halted,110
online upgrade restarting system,109
PCI bridge ASIC self-test failure,126
PCI subsystem hardware failure,126
persistent mem disabled,126
pilot 2 contrlr not supported,109
read failure,110
recovery ROM autoash done,122
recovery ROM autoash failed,122
recovery ROM autoash started,121
redundancy active active Controller,111
redundancy active standby controller, 111
redundancy failed cache DIMMS mismatch,
11 4
redundancy failed cache size mismatch,112
redundancy failed rmware lockup,113
redundancy failed hardware failure, 111
redundancy failed I/O request error,113
redundancy failed mismatch rmware,112
redundancy failed mismatch hardware,112
redundancy failed no second controller,113
redundancy failed out of memory,113
redundancy failed PCI bus error,113
redundancy halted expand active,112
redundancy halted rmware cloned,112
remove other controller now ,114
replacement drive found box,117
restarting system,108
ROM cloning done,122
ROM cloning failed,122
ROM cloning started,122
scanning for SCSI devices,110
SCSI subsystem hardware failure,110
smart drive alert box,117
spares cleared,120
startup complete,107
storage box,124
storage box EMU not responding,125
storage box EMU version,125
storage box fan failed
,124
storage box fan hot inserted,124
storage box fan hot removed,124
storage box ash done,123
storage box ash failed,123
storage box ash started,123
storage box overheated,125
storage box overheating,125
storage box power supply added,125
storage box power supply failed,125
storage box power supply ok,125
storage box power supply removed,125
storage box temperature ok,124
storage fan degraded,124
system halted for cache error,116
system name,108
too many volumes detected,120
uncorrected ECC memory error seen,126
unknown I/O module detected,126
validcachedatafoundatpower-up,114
volume expansion disabled,119
volume expansion failure,119
volume initializing parity,119
volume media exchanged,119
volume rebuild failure,119
volume state deleted,119
volume state disabled,118
volume state expansion active,118
volume state failed,118
volume state interim recovery,118
volume state missing drives,119
volume state ok,118
volume state rebuilding,118
volume state waiting to expand,118
volume state waiting to rebuild,118
volume state wrong drive replaced,119
write failure, 111
controller display, at startup,56
controller, redundancy requirements,39
154