HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Preparing the s
ervers
When preparing
servers for the MSA1510i, be sure to do the following tasks. For detailed installation and
conguration
information, see the documentation provided with the server or software tools.
Be sure to reco
rd information about the servers that will connect to the MSA1510i.
(“Server information on page 146)
Verify that the servers, Ethernet NICs, Ethernet switches, operating system version, and service
packs are supported for use with the MSA1510i. For details, see the HP StorageWorks
MSA1510i compatibility guide, located on the Manuals page of the MSA1510i support website:
h
ttp://www.hp.com/support.
Install one
or more Ethernet NICs in each server that will access the MSA1510i. For instructions,
refer to the documentation provided with the NIC or the server.
NOTE:
In multipath congurations, obtain and install a separate 1000BaseT Ethernet NIC cards in the server.
Using the two ports embedded in the server does not truly provide separate paths.
Install all operating-system-specic service packs, patch kits, or other required tools. Some of the
components that must be installed on your server may include:
•Initiatorsoftware
Multipathing Device SpecicModule(DSM)
Internet browser
NOTE:
In multipath congurations, install the multipathing software components on each server with access
to the MSA1510i.
Install HP system management and monitoring tools.
HP Systems Insight Manager (HP-SIM) is a client/server application used to remotely manage
HP hardware in network environments. HP-SIM reports hardware fault conditions (both failure
and pre-failure) and collects data for reporting and graphing. HP-SIM also provides base-level
management of HP clients, printers, and selected storage. For more information, see the
HP-SIM website: h
ttp://www.hp.com/go/hpsim.
Preparing the switches
When conguring the switches, consider setting up VLANs to control access to the MSA1510i storage
targets. For detailed installation and conguration instructions, see the documentation provided with
the sw
itch.
Be sure to record information about the switches that will connect to the MSA1510i. (Network switch
information)
NOTE
:
For op
timum performance from the MSA1510i, use 1000BaseT switches and qualied Category 5e (or
better) Ethernet cables.
Installing MSA hardware options
If your plans include adding any of the available option kits to the MSA1510i, install them now. It is
easier to install these options before racking the MSA.
1510i Modular Smart Array installation and user guide
39