HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Conguration b
est practices
Maintain detailed records of your iSCSI storage network, including information about the
initiators, targets (including which LUNs are mapped to the targets), IP address assignments, and
portals and po
rtal groups. Be sure to note which initiators are accessing which targets through
which portal groups using which IP addresses and protected by which Access Control List (ACL)
and virtual Local Area Networks (VLAN).
When congur
ing switches, consider setting up VLANs to control access to the MSA1510i
storage targ
ets. For installation and conguration instructions, see the documentation included
with the switch.
For optimum performance from the MSA1510i, use 1000BaseT switches and qualied Category
5e (or bette
r) Ethernet cables.
Record information about the switches that will connect to the MSA1510i using the Network switch
information worksheet in the MSA1510i installation and user guide
Ensure that initiators and targets are on the same Layer 2 Ethernet LAN. This guarantees the
integrity of the data trafc and maintains high network performance levels.
Develop a
n IP addressing scheme for the management and data ports of the controller in slot 1 (the
front rig
ht slot), and the management and data ports of the controller in slot 2 (the front left slot).
When conguring the management and the data ports, assign the appropriate IP addresses to
the ports according to your IP addressing scheme.
When con
guring the portals and portal groups, and mapping the LUNs to a portal group,
congur
e the mapping to manually load balance ownership of the LUNs between the portal
groups (which are assigned to the physical data ports.
Conguration overview
Primar
yconguration tasks
Regard
less of the management tool used or operating system environment, the following tasks must be
completed:
Obtaining, installing, and conguring initiator and multipathing software components.
Updating MSA controller rmware.(Ifnecessary.SeeUpdating MSA rmware” on page 79.)
IMPORTANT:
MSA1510i v1.32 or earlier is active/passive rmware. For active/active, you must update the rmware
to v2.0 or later. To upgrade your system to active/active, obtain the MSA1510i Support CD from the
MSA1510i Support page: h
ttp://www.hp.com/go/support. Upgrade instructions are provided on
the CD
.
Conguring the MSA and its storage.
Changing the default IP address assigned to the management port of each controller (usually MA0
and MB0) to be in the same LAN segment as the network servers. (If necessary.) (See
Changing the management port IP address through the MSA1510i controller display panel on page 102.)
Creating the logical storage units (LUNs).
Entering global controller settings, such as setting the read/write cache ratio, setting the
rebuild/expand priority, and setting the redundancy level.
Identifying the operating system type (also called Host Mode or Prole) of each initiator that will
access the MSA. This ensures that the MSA will communicate properly with that host.
Verifying that the desired initiators are detected by the MSA.
Creating Access Control Lists (ACLs) to isolate the storage from unauthorized access. These settings
indicate, by NIC, which LUNs the NIC can access.
1510i Modular Smart Array installation and user guide
61