HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)
IMPORTANT:
If you encounter any problems during the firmware update process, stop and contact HP technical
support. See for support contact information.
Updating MSA firmware using the SMU
NOTE:
For complete information about accessing and using the SMU, see the
HP Storage Management Utility
user guide
.
1. Determine which version firmware is currently installed on the MSA by using one of the following
methods:
• With the array controller powered on, press the arrow buttons on the front of the controller until
the following message is displayed:
00 Array Controller Firmware ver <version>.
•FromtheSMU,selectView MSA1510i Controller. Then, read the Device Information in the right
pane of the screen and look for the Firmware Version.
2. Obtain the latest firmware files and save to a temporary location on the host:
a. Navigate to the MSA1510i support page: h
ttp://www.hp.com/go/support.
b. Click the title description of the download option to display important information about the
update.
•ClicktheDescription tab for a brief overview about the download.
•ClicktheRelease Notes tab for detailed information about the download, including
version information, compatibility information, a summary of changes, important notes,
service considerations, and installation precautions.
IMPORTANT:
Be sure to review the online release notes and readme files for last-minute notifications
about the update.
c. After reviewing the release notes for update, click Download and follow the on-screen instructions
to save the download bundle to a temporary directory on the server.
NOTE:
For downloaded ISO images, create a CD from the downloaded ISO file using a CD
burning tool with the ability to burn a CD from an ISO file. Do not simply copy the
ISO file to a blank CD.
3. Schedule a maintenance window for the update.
4. Ensure
that there is a valid, recent backup of the system.
5. Stop all host traffictotheMSAarray.
6. If the MSA has not been restarted in the last six months, power cycle the array.
82