HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

IMPORTANT:
If you encounter any problems during the rmware update process, stop and contact HP technical
support. See for support contact information.
Updating MSA rmware using the SMU
NOTE:
For complete information about accessing and using the SMU, see the
HP Storage Management Utility
user guide
.
1. Determine which version rmware is currently installed on the MSA by using one of the following
methods:
With the array controller powered on, press the arrow buttons on the front of the controller until
the following message is displayed:
00 Array Controller Firmware ver <version>.
•FromtheSMU,selectView MSA1510i Controller. Then, read the Device Information in the right
pane of the screen and look for the Firmware Version.
2. Obtain the latest rmware les and save to a temporary location on the host:
a. Navigate to the MSA1510i support page: h
ttp://www.hp.com/go/support.
b. Click the title description of the download option to display important information about the
update.
•ClicktheDescription tab for a brief overview about the download.
•ClicktheRelease Notes tab for detailed information about the download, including
version information, compatibility information, a summary of changes, important notes,
service considerations, and installation precautions.
IMPORTANT:
Be sure to review the online release notes and readme les for last-minute notications
about the update.
c. After reviewing the release notes for update, click Download and follow the on-screen instructions
to save the download bundle to a temporary directory on the server.
NOTE:
For downloaded ISO images, create a CD from the downloaded ISO le using a CD
burning tool with the ability to burn a CD from an ISO le. Do not simply copy the
ISO le to a blank CD.
3. Schedule a maintenance window for the update.
4. Ensure
that there is a valid, recent backup of the system.
5. Stop all host trafctotheMSAarray.
6. If the MSA has not been restarted in the last six months, power cycle the array.
82
Operation and management