HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

11 . View the messages displayed on the array controller LCD panel during startup to conrm that the
rmware was installed successfully and that the array controller restarts successfully.
NOTE:
In dual-controller congurations, rmware on the two controllers is compared each time
theMSAchassisisrestarted.Iftheversionsaremismatched,thesystempromptstoclone
the rmware on the controller with the latest version over to the controller with the earlier
version rmware. (For the system to operate in a dual-controller mode, rmware on the
controllers must match.)
The following message is displayed on the LCD panel of the controller with the earlier
rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware.Duringthecloningprocess,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
Updating MSA rmware using the MSA-CLI
This out-of-band, MSA-based updating method is supported for use in most environments, with a few
limitations.
IMPORTANT:
Before using this method to update the rmware, make note of the following:
The custom CLI cable, shipped with the MSA, must be available to establish the serial connection to
the MSA. This command is not available through SSH or Telnet.
Thehostcomputermustsupportthe1kXmodem(Ymodem)protocol.
Because this updating method uses a serial connection to the MSA, it is substantially slower than
other updating methods. The preferred method of updating MSA1510i rmware is with the SMU. See
the
HP Storage Management Utility user guide
for more information.
NOTE:
For more information about accessing and using the CLI, see the
MSA1510i Modular Smart Array
Command Line Interface user guide
.
To update MSA controller rmware or MSA storage enclosure rmware:
1. Determine which version rmware is currently installed on the MSA by using one of the following
methods:
With the array controller powered on, press the arrow buttons on the front of the controller until
the following message is displayed:
00 Array Controller Firmware ver <version>.
From the MSA-CLI, enter the show version command. MSA1510i Firmware Revision is
included in the displayed system information.
84
Operation and management