HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

10. In the Send File window:
a. Click Browse, navigate to the directory in which you placed the rmware les, and then select
the rmware le.
b. Expand the Protocol drop-down box, and then select 1K Xmodem.
c. Click Send. A 1K Xmodem status window is displayed.
11 . Wait for a completion message to display.
For example, the following messages are displayed on the MSA controller LCD panel:
MSA1510i update: 307 FIRMWARE FLASH DONE
MSA20 upda
te: 313 FIRMWARE FLASH DONE ON BOX <n> (Each attached storage enclosure
is updated one at a time, in sequential box number order.)
NOTE:
Do not interfere with or cancel the download process. Interrupting the download process
might corrupt the rmware.
12. Restart the MSA and its attached storage enclosures storage system by doing the following (newly
downloaded rmware is not activated until the MSA is restarted):
IMPORTANT:
When powering down the MSA storage system, you must do so in the following sequence.
If the MSA chassis is powered on before the hard drive storage enclosures complete their
startup routines, conguration settings and data stored on the enclosures will not be visible.
a. Press and hold down the MSA Power On/Standby button for approximately ve seconds to
place the MSA in Standby mode.
b. Power off all storage enclosures attached to the MSA.
c. Wait approximately two minutes to ensure that the hard disk drives in the enclosures stop
rotating.
d. Restart all storage enclosures attached to the MSA.
e. Wait approximately four minutes to allow the enclosures to complete their startup routines.
f. Press and release the MSA Power On/Standby button to restart the MSA.
g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA
controller LCD panel.
1510i Modular Smart Array installation and user guide