HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Recovering corr
upted MSA controller rmware
If the controll
er detects a rmware corruption, the following message is displayed on the LCD panel:
ERROR: ROM CORRUPT
SEND IMG VIA XMODEM
To recover the co
ntroller, you must obtain a current rmware image and send it to the controller using a
serial connection.
1. Go to the MSA1510i support website and obtain the latest controller rmware.
NOTE:
If you are not yet registered, select the option to receive e-mail notications, advisories, and
support alerts about MSA system hardware, rmware, drivers, and software components.
This alert not
ication system is a one-way broadcasting method used to distribute important
notices about
HP products. Information about your MSA is not requested when subscribing
to this service.
2. Establish a serial connection to the affected controller:
•UsethecustomCLIconguration cable shipped with the MSA.
Use a terminal emulator program that supports the Xmodem protocol, such as HyperTerminal.
Use the following emulator connection settings:
•Bitspersecond:19200
•Databits:8
•Parity:None
•Stopbits:1
Flow control: None
A blank emulator window is displayed—no CLI prompt is displayed.
1510i Modular Smart Array installation and user guide
91