HP StorageWorks 2000 G2 Modular Smart Array Controller Module Replacement Instructions (500916-003, July 2010)

6. Turn the thumbscrews until the screws disengage from the module.
7. Rotate both latches downward to disconnect the module from the
internal connector.
8. Pull the module straight out of the enclosure.
Transporting CompactFlash
nl
(single-controller configurations only)
CAUTION:
CompactFlash must stay with the same enclosure. If the
CompactFlash is used/installed in a different enclosure, data
loss or corruption will occur.
1. If the controller has failed or does not start, make sure that
transporting the cache is the appropriate action to take as specified
in the user guide.
2. Carefully remove the CompactFlash from the controller, label it
Data, and set it aside.
3. Carefully remove the CompactFlash from the replacement controller,
and set it aside.
4. Insert the CompactFlash that you removed from the failed controller
and labeled Data into the replacement controller.
Page 3