HP StorageWorks MSL4048 Tape Library getting started guide (AH560-96001, March 2007)

Optional: Installing the tabletop conversion cover
2
CAUTION! Operating the Tape Library on a flat
surface without the tabletop conversion kit may
cause errors or damage to the Library.
IMPORTANT! The shipping lock must be removed for the
robotics to work properly. A robot move error is
displayed if the shipping lock is not removed.
The shipping lock prevents the robotic transport
mechanism from moving during shipment, and must be
removed and stored before powering on the Library.
Locate the tape holding the lock at the top of the
Library. Remove the tape, then remove the lock and
store it as shown.
Removing and storing the shipping lock
1
If you are installing the Library in a rack, skip this step.
Place the cover on the work surface behind the Library.
Slide the Library into the cover until the front panel of
the Library is aligned with the cover.
Tighten the four captive screws on the Library front
panel until the cover is secure.
Skip to Step 7.
Determining your rack type
You will need a #2 and a #3 Phillips screwdriver, the
two rack rails, and the packet of M6 screws and clip
nuts appropriate for your rack.
The HP System/E rack has 7.1 mm round holes in
the rack column. Choose the bag labeled HP Rack
System/E.
The HP 5000 and 10000 racks have 9.5 mm square
holes in the rack column. Choose the packet labeled
HP Rack 5000, 10000.
3