HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
tracking the cartridge usage count. If the deviceknows the usage count for all of the cleaning
cartridges, the device will choose the one with the highest usage count.
Auto cleaning is disabled by default. You can enable automatic cleaning even if there are no
cleaning cartridges in the device. In this case, the device will display a warning message.
CAUTION: Only enable automatic cleaning in either the backup application or the device, not
both.
To configure automatic cleaning:
1. From the Home screen, press Previous or Next until the screen displays Configuration. Press
Enter to select.
2. Press Previous or Next until the screen displays Configure Auto Cleaning. Press Enter to select.
3. The screen displays Auto Cleaning Disabled or Auto Cleaning Enabled depending on the
current setting. To change the auto cleaning configuration, press Enter.
4. Press Previous or Next until the screen displays the configuration you want. Press Enter.
Restoring factory defaults (Configuration > Restore Defaults)
The device can reset most of the configurations to the factory defaults, while retaining the settings
necessary to use the RMI. The device will perform an inventory after the defaults are restored.
The restored settings are:
SCSI addresses: The SCSI ID for the bottom drive is 4; the SCSI ID for the top drive is 5. The
library will no longer recall a drive that has been removed.
Fibre Channel drive configuration: Automatic speed, auto port type
Master drive: reset to Drive 1 or the lowest numbered existing drive
Drive power: all drives powered on
Active slots: maximum possible
Library mode: Automatic
Loop: No
Event log levels and filter: continuous trace and all levels and filters active (for HP Service use
only)
Barcode reader label length: 8
Barcode reader alignment: Left
Error recovery: On
Mailslot configuration: mailslot disabled
Auto clean: disabled
SNMP: disabled, but saved addresses to not change
E-mail notification: disabled, but configurations retained
The following settings are not reset:
Administrator password
Network settings (network is always enabled)
Date and time
To restore the factory defaults:
1. From the Home screen, press Previous or Next until the screen displays Configuration. Press
Enter to select.
2. Press Previous or Next until the screen displays Restore Defaults. Press Enter to select.
114 Operating the tape library